MULTIMACH VLV, INTERMEDIATE & END PLATES-- ELPN VALVES
elpn, 5/2 , bist. , Ø 4, 24 VDC
elpn, 5/2 , single sol., Ø 4, 24 VDC
elpn, 5/3 CC, single sol., Ø4, voltVDC MM
elpn, n.2 3/2 NC, single sol., Ø4,VDC MM
elpn, n.2 3/2 NO, single sol., Ø4,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø4,VDC MM
elpn, 5/2 , bist. , Ø 6, 24 VDC
elpn, 5/2 , single sol., Ø 6, 24 VDC
elpn, 5/3 CC, single sol., Ø6, voltVDC MM
elpn, n.2 3/2 NC, single sol., Ø6,VDC MM
elpn, n. 2 3/2 NO, single sol., Ø6,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø6,VDC MM
elpn 5/2, ø8, bistabile,VDC MM
elpn, 5/2 , single sol.spring return, Ø 8, 24 VDC MM
elpn, 5/3 CC, single sol., Ø8, voltVDC MM
elpn, n.2 3/2 NC, single sol., Ø8,VDC MM
elpn, n.2 3/2 NO, single sol., Ø8,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø8,VDC MM
elpn, 5/2 , single sol., Ø 4, 24 VDC
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00150 |
Insulation class | F 155 |
Max input pressure (bar) | 007 |
Max temperature (°C) | 60 |
Min input pressure (bar) | 02 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 4 |
Way scheme | 5/2 |
elpn, 5/3 CC, single sol., Ø4, voltVDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00150 |
Insulation class | F 155 |
Max input pressure (bar) | 007 |
Max temperature (°C) | 60 |
Min input pressure (bar) | 02 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 4 |
Way scheme | 5/3 |
elpn, n.2 3/2 NC, single sol., Ø4,VDC MM
elpn, n.2 3/2 NO, single sol., Ø4,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø4,VDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00150 |
Insulation class | F 155 |
Max input pressure (bar) | 007 |
Max temperature (°C) | 60 |
Min input pressure (bar) | 02 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 4 |
Way scheme | 3/2x2 |
elpn, 5/2 , bist. , Ø 6, 24 VDC
elpn, 5/2 , single sol., Ø 6, 24 VDC
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00400 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 6 |
Way scheme | 5/2 |
elpn, 5/3 CC, single sol., Ø6, voltVDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00400 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 6 |
Way scheme | 5/3 |
elpn, n.2 3/2 NC, single sol., Ø6,VDC MM
elpn, n. 2 3/2 NO, single sol., Ø6,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø6,VDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00400 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 6 |
Way scheme | 3/2x2 |
elpn 5/2, ø8, bistabile,VDC MM
elpn, 5/2 , single sol.spring return, Ø 8, 24 VDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00800 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 8 |
Way scheme | 5/2 |
elpn, 5/3 CC, single sol., Ø8, voltVDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00800 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 8 |
Way scheme | 5/3 |
elpn, n.2 3/2 NC, single sol., Ø8,VDC MM
elpn, n.2 3/2 NO, single sol., Ø8,VDC MM
elpn, n.2 3/2, 1 NC and 1 NO, single sol., Ø8,VDC MM
Coils voltage | 24VDC |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00800 |
Insulation class | F 155 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 60 |
Min input pressure (bar) | -0.99 |
Min temperature (°C) | -10 |
Power | 1.2 W |
Protection degree | IP 51 |
Push-in fitting for pipe (Ø) | 8 |
Way scheme | 3/2x2 |