SOLENOID VALVES PIV IN LINE-- PIV.B Ø 13 MM IN LINE, 1/8"
PIV.B Ø 13 mm in line, 3/2 NC, 1/8'', Ø 1.6 Kv 1.4
PIV.B Ø 13 mm in line, 3/2 NC, 1/8'', Ø 1.6 Kv 1.2
PIV.B Ø 13 mm in line, 3/2 NC, 1/8'', Ø 2.4 Kv 2.8
PIV.B Ø 13 mm in line, 3/2 NC, 1/8, Ø 3 Kv 4
Flow-rate at 6 bar DP 1 bar (Nl/min) | 92.4 |
Insulation class | F 155 |
Max drive frequency (Hz) | 15 |
Max input pressure (bar) | 017 |
Max temperature (°C) | 50 |
Max torque for coil nut (Nm) | 1 |
Min temperature (°C) | -15 |
Protection degree | IP 65 EN60529 |
Response time (ms) | 10÷15 |
Threaded port | 1/8'' |
Voltage | 24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
Voltage tolerance | -10% ÷ 15% |
Way scheme | 3/2 |
PIV.B Ø 13 mm in line, 3/2 NC, 1/8'', Ø 1.6 Kv 1.2
Flow-rate at 6 bar DP 1 bar (Nl/min) | 79.2 |
Insulation class | F 155 |
Max drive frequency (Hz) | 15 |
Max input pressure (bar) | 012 |
Max temperature (°C) | 50 |
Max torque for coil nut (Nm) | 1 |
Min temperature (°C) | -15 |
Protection degree | IP 65 EN60529 |
Response time (ms) | 10÷15 |
Threaded port | 1/8'' |
Voltage | 24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
Voltage tolerance | -10% ÷ 15% |
Way scheme | 3/2 |
PIV.B Ø 13 mm in line, 3/2 NC, 1/8'', Ø 2.4 Kv 2.8
Flow-rate at 6 bar DP 1 bar (Nl/min) | 184.8 |
Insulation class | F 155 |
Max drive frequency (Hz) | 15 |
Max input pressure (bar) | 010 |
Max temperature (°C) | 50 |
Max torque for coil nut (Nm) | 1 |
Min temperature (°C) | -15 |
Protection degree | IP 65 EN60529 |
Response time (ms) | 10÷15 |
Threaded port | 1/8'' |
Voltage | 24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
Voltage tolerance | -10% ÷ 15% |
Way scheme | 3/2 |
PIV.B Ø 13 mm in line, 3/2 NC, 1/8, Ø 3 Kv 4
Flow-rate at 6 bar DP 1 bar (Nl/min) | 0264 |
Insulation class | F 155 |
Max drive frequency (Hz) | 15 |
Max input pressure (bar) | 006 |
Max temperature (°C) | 50 |
Max torque for coil nut (Nm) | 1 |
Min temperature (°C) | -15 |
Protection degree | IP 65 EN60529 |
Response time (ms) | 10÷15 |
Threaded port | 1/8'' |
Voltage | 24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
Voltage tolerance | -10% ÷ 15% |
Way scheme | 3/2 |