FR SKILLAIR 200
FR Skillair 200 1/4'' 5µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 5µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 20µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 20µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 50µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 50µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 5µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 5µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 20µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 20µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 50µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 no end plates 50µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/4'' 5µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 5µm 08 bar autodrain by depress.
SPECIFICATION
FR Skillair 200 1/4'' 20µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 20µm 08 bar autom. drain depress.
SPECIFICATION
FR Skillair 200 1/4'' 50µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 50µm 08 bar autom. drain depress.
SPECIFICATION
FR Skillair 200 1/4'' 5µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 5µm 012 bar autom. drain depress.
SPECIFICATION
FR Skillair 200 1/4'' 20µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 20µm 012 bar autom. drain depress.
SPECIFICATION
FR Skillair 200 1/4'' 50µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 no end plates 50µm 012 bar autom. drain depress.
SPECIFICATION
FR Skillair 200 3/8'' 5µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' 20µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' 50µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' 5µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' 20µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' 50µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 3/8'' .5µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 3/8'' 20µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 3/8'' 50µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 3/8'' 5µm 0128 bar depression autodrain
SPECIFICATION
FR Skillair 200 3/8'' 20µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 3/8'' 50µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 5µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 20µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 50µm 08 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 5µm 012bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 20µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 50µm 012 bar semi- autodrain
SPECIFICATION
FR Skillair 200 1/2'' 5µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 20µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 50µm 08 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 5µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 20µm 012 bar depression autodrain
SPECIFICATION
FR Skillair 200 1/2'' 50µm 012 bar depression autodrain
SPECIFICATION
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 5µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 20µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 20µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 50µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 50µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 5µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 5µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 1/4'' 20µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 20µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 1/4'' 50µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 50µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 1/4'' 5µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 5µm 08 bar autodrain by depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 20µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 20µm 08 bar autom. drain depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 50µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 50µm 08 bar autom. drain depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
FR Skillair 200 1/4'' 5µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 5µm 012 bar autom. drain depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 1/4'' 20µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 20µm 012 bar autom. drain depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 1/4'' 50µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/4'' |
FR Skillair 200 no end plates 50µm 012 bar autom. drain depress.
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
FR Skillair 200 3/8'' 5µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 20µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 50µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 5µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 20µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 50µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' .5µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 20µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 50µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 5µm 0128 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 20µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 3/8'' 50µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 3/8'' |
FR Skillair 200 1/2'' 5µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 20µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 50µm 08 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 5µm 012bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 20µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 50µm 012 bar semi- autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 5µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 20µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 50µm 08 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 08 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 5µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 05 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 20µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 20 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |
FR Skillair 200 1/2'' 50µm 012 bar depression autodrain
SPECIFICATION
Boul capacity (cm3) | 45 cm3 |
Degree of filtration (µm) | 50 µm |
Flow-rate at 6 bar DP 0.5 bar (Nl/min) | 01600 |
Flow-rate at 6 bar DP 1 bar (Nl/min) | 3000 |
Manometer port | 1/8'' |
Max input pressure (bar) | 013 |
Max temperature (°C) | 50 |
Min temperature (°C) | -10 |
Setting range (bar) | 12 |
Threaded Port | 1/2'' |